Products

PRODUCT DESCRIPTION

Protect-a-set (code 836.02) and Octopus 2 (other codes) are polyurethane, transparent, supple with low dead space double-lumen extension tubes for IV catheters (peripheral or central venous) fitted with one or 2 Bionector.

To identify the different infusion lines, each line has a hub or a clamp of a different colour.

They allow to connect to the catheter several independant IV lines.

Code 836.02 is a double lumen extension tube with 1 non-return valve, 1 hub with Bionector and 1 clamp (white).

Length of tubes: 6 cm / 10 cm.

Code 841.232 is a double lumen extension tube with 2 non-return valves, 2 Bionector and 2 clamps (green). 

Length of tubes: 3 cm / 3 cm.

Code 841.24 is a double lumen extension tube with 2 Bionector and 2 clamps (white). 

Length of tubes: 10 cm / 6 cm.

Code 841.25 is a double lumen extension tube with 1 Bionector and 2 clamps (white). 

Length of tubes: 10 cm / 6 cm.

Code 841.26 is a double lumen extension tube with 2 Bionector and 2 clamps (white). 

Length of tube : 6 cm / 6 cm.

Code 841.264 is a double lumen extension tube with 2 Bionector and 2 clamps (green and orange). 

Length of tubes: 10 cm / 10 cm.

Code 841.266 E is a double lumen extension tube with 2 Bionector and 2 roberts clamps (white).

Length of tubes: 6 cm / 6 cm

Code 842.209 is a double lumen extension tube with 1 anti-return valve, 2 Bionector and 2 clamps (green and orange). The end without anti-retourn valve allows the sampling blood.

Length of tubes: 6 cm / 6 cm

Used for peripheral cannula care, Octopus 2 has the following advantages:

- Eliminates the risk of access-associated needle-stick injury

- Reduces the risk of cannula movement in the vein causing mechanical vein irritation

- Negates the need to use the cannula injection port (non disinfectable), Bionector is disinfectable

- Eliminates the need to use a 3-way tap to run simultaneous compatible solutions

- Provides closed system (avoiding blood reflux) when accessing the catheter

- PUR material (no PVC, DEHP-free - no release of softeners)

Anti-return valves avoid reflux of fluids or drugs beyond the valve during multiple infusions.

Bionector can be disinfected with most of the antiseptic solutions (example: 70% alcohol). Avoid using antiseptic containing both alcohol and oxygenated water.

For more information about Bionector, please refer to technical file code 896.

Octopus with Bionector are also available with 1 lumen (code 5222.014), 3 lumen (codes 841.34/364-842.311/312/306), 4 lumen (code 842.414) and 5 lumen (code 842.514). 

Contains Latex: No

Contains DEHP: No

Contains products of animal or biological origin: No

Pyrogen-free: Yes

  Extension tube Lumen 1 Lumen 2
Code Int. Ø
mm
Ext. Ø
mm
Length
cm
Prim. vol.
ml
Total priming volume
ml
Flowrate
ml/min
Length
cm
Int. Ø
mm
External diameter
mm
Priming volume
ml
Length
cm
Int. Ø
mm
External diameter
mm
Priming volume
ml
Flowrate
ml/min
  841.232 - - - - 0.50 78 3 1.50 2.50 0.30 3 1.50 2.50 0.30 78
  841.233 1.50 (x2) 2.50 (x2) 3 (x2) 0.29 (x2) - - - - - - - - - - -
  841.24 - - - - 0.45 15 6 0.55 1.55 0.12 10 1.60 2.60 0.35 80
  841.25 - - - - 0.43 11 6 0.55 1.50 0.12 10 1.66 2.60 0.33 190
  841.26 - - - - 0.52 70 6 1.60 2.60 0.27 6 1.60 2.60 0.27 70
  841.264 - - - - 0.57 75 10 1.50 2.50 0.57 10 1.50 2.50 0.34 75
  841.265 1.50 (x2) 2.50 (x2) 10 (x2) 0.33 (x2) - - - - - - - - - - -
  841.266 E 1.50 (x2) 2.50 (x2) 6 (x2) 0.32 (x2) 0.54 - - - - - - - - - -
  842.209 - - - - 0.58 73 6 1.50 2.50 0.36 6 1.50 2.50 0.33 78
PRODUCT DETAILS
  • Category:
    I.V. Therapy
RELATED PRODUCTS